ASHRAE 90.1-2025 brings new rooftop unit and heat pump ratings in 2029

ASHRAE Standard 90.1-2025 folds in more than 100 addenda and adds annualized ratings for rooftop units and heat pumps that take effect in 2029. Much of the change is about measurement, and adoption trails publication. Massachusetts' draft 2027 stretch code still amends 90.1-2019, so equipment specs are likely to feel the new edition before permit reviews do.

This story was produced through MarketScale. See how Building Management teams put it to work with Customer Stories & Case Studies.

By MarketScale Newsroom · Ashrae Standard 90.1-2025Ivec and Ivhe RatingsMassachusetts Stretch Energy CodeLighting-hvac Integration
Share
ASHRAE 90.1-2025 brings new rooftop unit and heat pump ratings in 2029

Key takeaways

01

From 2029, ASHRAE 90.1 rates unitary cooling equipment on the annualized IVEC metric and gives heat pumps their first annualized heating metric, IVHE, with a cold-climate version called IVHEC.

02

Massachusetts' draft 2027 stretch code still amends ASHRAE 90.1-2019, two editions back, so the 2025 edition reaches owners through equipment specs and design contracts well before it reaches many permit desks.

03

Energy Cost Budget models under 90.1-2025 must use actual utility rates or contracted energy prices where available, which ties a building's energy supply contract directly to its design compliance model.

Free workspace

Turn your Building Management expertise into content.

Record interviews, organize footage, and write with AI on a free trial of the MarketScale platform for qualifying companies. No demo required, no credit card.

Try it Free

In 2029, the yardstick for rooftop units changes. Under the 2025 edition of ANSI/ASHRAE/IES Standard 90.1, unitary cooling equipment will be judged on a new annualized metric called IVEC. Heat pumps get an annualized heating metric, IVHE, for the first time, with a cold-climate version called IVHEC. The American National Standards Institute's summary of the revision says the edition folds in more than 100 addenda approved since 2022.

Read line by line, much of the 2025 edition runs through measurement: how equipment is rated, how energy data appears on an operator's screen, and which utility prices go into a compliance model. That puts the facilities director planning a replacement cycle, and the engineer writing the specification, closer to this edition than the code official who will eventually enforce it.

Scope matters here. The standard covers new buildings, but also new systems and equipment in existing buildings and new equipment that is part of industrial or manufacturing processes. A rooftop unit swap on a 1980s office is inside the fence once a jurisdiction adopts the edition.

New yardsticks for unitary equipment

The equipment changes run wide. Minimum efficiencies rise for unitary systems, water-source heat pumps, cooling towers, fans and dedicated outdoor air systems, bringing the tables in line with current federal test procedures and industry rating standards. Water-source heat pumps pick up a new IEER metric, and DOE-regulated products are now folded into the Section 6 and 7 tables where they apply. Fan power limits tighten across most system types, with a new procedure for calculating fan system limits that puts the emphasis on how efficiently air is distributed.

The unitary metric carries the most weight because of where those units sit. A lighting-HVAC integration white paper published in October 2026, citing the U.S. Energy Information Administration's 2018 Commercial Buildings Energy Consumption Survey, puts rooftop units as serving more than 60% of commercial floorspace. A rating change for that category shows up on a lot of roofs.

An annualized metric rates equipment across a year of operating conditions instead of at a single test point. In 90.1-2025, IVEC applies to unitary cooling and IVHE (IVHEC in cold climates) to heat pump heating, and both take effect in 2029.

For a procurement lead, the practical issue is comparison. Bids gathered in the years around 2029 could describe similar equipment under different metrics, and a quote rated on the old basis cannot be lined up directly against one rated on the new. Asking which metric a submittal uses is a short email that saves a confused bid tab.

Controls data has to reach the operator

Section 8, the power chapter, adds provisions for electric vehicle spaces, receptacle controls and energy monitoring. One line stands out for anyone who runs a building: where direct digital control systems are installed, their data must now be displayed graphically so operators can actually watch energy use. A DDC system that logs everything and shows nothing no longer meets the intent.

Lighting gets a structural rewrite. Section 9 now separates lighting power density limits from control requirements, updates interior and exterior density values, revises decorative and specialty lighting values to reflect how common LEDs have become, and expands daylight-responsive controls. Occupancy provisions and the thresholds that trigger automatic controls were revised too. On the HVAC side, lower minimum VAV airflow turndown ratios target part-load operation, and health care spaces get new unoccupied setback control requirements alongside targeted economizer exceptions for specific health care uses.

Those pieces point toward lighting and HVAC sharing occupancy information. The integration white paper notes that energy codes are beginning to require occupied-standby operation in certain space types, where lighting occupancy sensors can feed the building automation system. The savings case it cites is large, which is why the coordination problem is worth solving.

What lighting-HVAC integration is worth

48%
Average lighting energy savings from networked lighting controls
Up to 30%
HVAC energy savings when lighting controls are tied to HVAC
About 87%
Share of US commercial buildings at 25,000 sq ft or less
60% to 70%
Share of energy in those buildings used by HVAC and lighting combined

DesignLights Consortium research; U.S. EIA 2018 CBECS, as cited in a 2026 lighting-HVAC integration white paper

The hard part is contractual. Lighting controls usually sit in the electrical contractor's Division 26 scope, while HVAC controls live in Division 23 or 25, and the white paper describes integration falling into the gap with each side assuming the other has it. The protocols differ as well: lighting networks often run Bluetooth mesh, Zigbee or DALI, while HVAC controls run BACnet, LonWorks or Modbus.

The paper lays out three ways across. Contact closure, a simple relay signal from an occupancy sensor to the HVAC controller, is vendor-agnostic but binary and one-way, and it suits small and medium buildings with tight budgets and thin staff. A BACnet-based building management system sits at the other end, reading and writing points across both systems from one dashboard. The third route pairs a smart thermostat with open-standard networked lighting controls. For the owner of a 20,000-square-foot building with one rooftop unit per zone, the first or third option is likely to be the realistic one.

Before bid, name one party responsible for the integrated lighting-HVAC sequence of operation and require it to be tested during commissioning. 90.1-2025 clarified commissioning requirements across Sections 4 through 10 in work with SSPC 300, which gives that clause something to point to.

Real utility prices enter the model

Teams that comply through modeling face a quieter but consequential change. The Energy Cost Budget path now requires actual utility rates or contractual energy prices, where available, in place of generic national averages. Modeling rules for envelope, mechanical and lighting assumptions in the budget building were also aligned more closely with the prescriptive sections. A building on a negotiated supply contract could therefore see different measures pencil out than the same design priced at a national average, which means the energy buyer's contract now belongs in the design team's inputs.

Appendix G, the performance rating method, keeps its role as a baseline but with expanded HVAC baseline definitions, revised modeling for elevators, dehumidification, ventilation and purchased heating and cooling, and updated building performance factors. Simulation software now has to meet performance-based qualification criteria aligned with ASHRAE Standard 140 instead of being named tool by tool.

Many of the more ambitious changes carry no force on their own, and that limits how far this reading goes. Appendices M and N set out performance and prescriptive pathways to net zero operational energy emission buildings, and other informative appendices cover source energy and carbon-based compliance, but each is optional until a jurisdiction or rating authority adopts it. Their emissions accounting also leaves out refrigerant leakage and water use. The binding renewable change is narrower: higher minimum prescriptive on-site renewable capacity, plus limited off-site options by climate zone.

Massachusetts and the adoption gap

A November 18, 2026 draft from the Massachusetts Department of Energy Resources shows how a state actually moves. The proposed 2027 commercial stretch code and specialized opt-in code amend IECC 2021 and ASHRAE 90.1-2019.

Massachusetts is drafting its 2027 commercial stretch code on top of ASHRAE 90.1-2019, two editions behind the current 2025 edition, which gives a concrete picture of the distance between a published standard and a permit desk.

Massachusetts is drafting its 2027 commercial stretch code on top of ASHRAE 90.1-2019, two editions behind the current 2025 edition, which gives a concrete picture of the distance between a published standard and a permit desk.

Older base, sharper amendments. The draft requires buildings over 20,000 square feet to submit backstop compliance and thermal bridge derating calculations, while smaller buildings document the envelope through COMcheck. Mixed-fuel buildings following its Appendix CC must show an electric HVAC retrofit design, including the future equipment, supporting infrastructure and space allotments. Construction documents also have to locate EV-ready spaces and a solar-ready roof zone.

The transition rule is worth noting for anyone with a project in design. For six months after the effective date, complete permit applications can follow either the amended code or the February 2025 edition, but not a mix of both. After that window, only the new rules apply.

Checks for the next specification

  1. Confirm which edition of 90.1 or IECC the permit jurisdiction enforces, which local amendments sit on top, and whether a concurrency window lets the project choose.
  2. For operators planning unitary or heat pump purchases near 2029, it could help to ask which rating metric each quote uses.
  3. If the project models compliance, give the energy team the actual utility tariff or supply contract before the baseline run, not after.

The Massachusetts draft still shows its effective date as a bracketed blank. Once that date is set, the six-month clock starts, and projects already in design will have to decide which edition of the state code they are building to.

Featured companies

Your experts belong here

Every story in MarketScale Building Management starts with a company putting its facilities engineers, energy managers, and service technicians on the record. Buyers are already reading this topic. The only question is whose experts they find.

Owners and facilities teams pick on trust, and your engineers turn that trust into inbound conversations.

Book DemoSee how it works15 minutes, straight to a calendar.

About the author

MarketScale Newsroom
MarketScale NewsroomEditorial Team, MarketScale

The MarketScale Newsroom reports on the companies, technologies, and trends shaping 16 B2B industries. It turns primary sources and expert commentary into clear, useful coverage for the people doing the work.

B2B Weekly

The week in Building Management, and sixteen other industries, every Monday.

Ten stories, one-line takes, five minutes. Free.

Building Management: are you visible to AI?

Before they reach out, Building Management buyers ask AI engines which vendors to trust. Explore how your experts, customers, and partners can become useful content for buyers and AI search.

Free Trial

You just read one Building Management expert. Your company is full of them.

This article was produced through MarketScale. The same platform turns your facilities engineers, energy managers, and service technicians into the articles, video, and social content Building Management buyers are searching for. Start a free trial and see it with your own people. For qualifying companies, no credit card, no demo required.

NPS +73 · 1,000+ creators · 38+ countries

What your free trial includes

Hands-on access to the MarketScale platform
Media requests to your crowd, remote recording, AI writing tools
No demo required. No credit card.
For qualifying companies. Company confirmation required.

More Building Management Insights

XY Sense finds workers in half-full offices heading for one-person rooms

XY Sense finds workers in half-full offices heading for one-person rooms

Global office use hit 50% in September 2026, the highest since early 2020. Returning workers are leaving open desks for quiet one-person rooms. Teams rarely come in on the same days, so meetings default to video, and facilities teams should check scheduling before rebuilding floors.

  • 01Global office utilization reached 50% in September 2026, yet group spaces often hold one or two people while single-person rooms stay in demand.
  • 02With teams missing about a third of members on average and many following a “One Zoom, All Zoom” norm, some in-office time still happens on video—while XY Sense data shows strong demand for one-person rooms, which may reflect scattered schedules as much as space design.
  • 03Before converting open floor into enclosed rooms, check whether group spaces fill on days when whole teams are in; if they do, a common-hours policy may solve part of the problem without construction.

Nov 23, 2026

Carrier bundles 75F controls and AI with rooftop units for small buildings

Carrier's ClimaVision 3-MyStat Pro Pack sells Carrier rooftop units together with 75F controls, cloud software and AI tools for K-12 schools, offices and retail stores. Carrier expects to begin accepting orders this year. Shipments are planned for early 2027, putting building automation into the equipment purchase for small buildings that have often gone without it.

  • 01For a small school or store that has never had building automation, the easiest moment to add it may be the day the rooftop unit gets ordered, and Carrier's new pack is built on that bet.
  • 02Contractors may become key gatekeepers: with controls bundled into the rooftop quote, the person pricing the replacement can shape whether automation gets included—subject to owner sign-off.
  • 03The pack fits best where Carrier rooftop equipment is already the plan; a roof with mixed brands or a building keeping an existing automation system faces a different calculation.

Nov 22, 2026

Styrvel licenses NeoMesh to cut retrofit wiring for radiator controls

Buyers should test battery life.

  • 01In occupied buildings, retrofit costs are often driven by cabling or dedicated repeaters. NeoMesh’s pitch is a self-organizing mesh where battery devices relay traffic, aiming to avoid that extra infrastructure.
  • 02Which wireless retrofit fits depends on what is already in the walls.
  • 03No field results have been published for this kind of platform yet. Battery-life data from buildings already in service, and a clear answer on who replaces the cells, should be part of any pilot.

Nov 22, 2026

Explore More Building Management Insights

Read more expert perspectives from across Building Management.

Browse Building Management Hub

About the Expert

MarketScale Newsroom
MarketScale Newsroom

Editorial Team

MarketScale

The MarketScale Newsroom reports on the companies, technologies, and trends shaping 16 B2B industries. It turns primary sources and expert commentary into clear, useful coverage for the people doing the work.

For B2B teams

Your experts could be publishing here

Stories like this one run on content MarketScale captures from real practitioners. See how your team's expertise becomes coverage in Building Management and beyond.

Book a Demo

Or call us. No forms required. We pick up. 214-945-2512