Primary Causes and How to Prevent Them In boiler systems, steam that has completed its work condenses back into liquid water called condensate.  This is a high-purity, high-heat-content water that makes sense to recycle into the boiler system whenever possible to save money, water, energy, and chemicals. Protecting your plant’s condensate return system is vital…

This story was produced through MarketScale. See how Energy teams put it to work with Customer Stories & Case Studies.

Share
5 Steps to Protect Your Condensate System from Destructive Corrosion

Primary Causes and How to Prevent Them

In boiler systems, steam that has completed its work condenses back into liquid water called condensate. This is a high-purity, high-heat-content water that makes sense to recycle into the boiler system whenever possible to save money, water, energy, and chemicals.

Protecting your plant’s condensate return system is vital not only because it is a massive capital investment, but also because it can impact your day-to-day operations. The primary causes of destructive corrosion are carbonic acid attack and oxygen pitting. This corrosion can cause unexpected system shutdowns, affecting production timelines. Corroded systems are also less efficient, risking leaks and potentially catastrophic damage to the boiler as corrosion byproducts are carried into the feedwater.

Carbonic Acid Attack

Carbonic acid attack occurs when carbon dioxide from the steam condenses with the condensate to form carbonic acid. The carbon dioxide originates from the thermal breakdown of the carbonate alkalinity naturally present in the makeup water. Since the condensate is so pure, it requires very little dissolved carbon dioxide to lower the condensate pH into the corrosive range. The greater the makeup alkalinity, the greater the amount of carbon dioxide present in the steam, which increases the potential for carbonic acid attack in the condensate return system.

A carbonic acid attack is characterized by “grooving” of the condensate piping, which typically presents as thinning of the pipe at the threaded fitting. This same deterioration can also be spotted downstream of steam traps.

Oxygen Pitting

Another frequent type of corrosion is oxygen pitting, caused by dissolved oxygen in the condensate, which may occur when oxygen is not completely removed from the feedwater. Dissolved oxygen may also be present as a result of the vacuum created when steam condenses and cools, pulling oxygen-rich air into the system. Oxygen pitting is characterized by an intense, localized pitting that may or may not be covered by a tubercule. Due to the restrictive nature of oxygen pitting, it can cause rapid metal failure in a condensate system and is especially aggressive if the condensate pH is low.

Condensate System Protection

An effective protection and treatment plan can be divided into five main categories: neutralizing amines, filming amines, volatile oxygen scavengers, pretreatment equipment, and treatment program monitoring.

  1. Neutralizing Amines: The most common method of preventing a carbonic acid attack is through neutralizing amines. These chemicals, such as morpholine, cyclohexylamine, and diethylaminoethanol (DEAE), become volatile when mixing with steam and condense in the same way that the carbon dioxide does. They then neutralize the carbonic acid and increase the condensate pH. However, this process is ineffective in protecting against oxygen pitting.
  1. Filming Amines: A filming amine provides a protective barrier against both carbonic acid and oxygen. When using a filming amine, the pH is usually maintained between 6.0 and 7.5, so a neutralizing amine may still be required. Since the protective film formed by filming amines are susceptible to damage, it is critical to use corrosion coupons to monitor the effectiveness of corrosion control. Another significant limitation of filming amines is that they can be difficult to apply and cause fouling, particularly in systems where they have not been applied previously. A filming amine program should be initiated very gradually to help avoid this problem and users should be aware of the limitations.
  1. Volatile Oxygen Scavengers: A volatile oxygen scavenger such as DEHA (diethylhydroxyamine) can also be used to protect your condensate system against oxygen pitting. DEHA has fewer limitations than filming amines and can provide even better results since it both scavenges oxygen and passivates system metals, making them less susceptible to corrosion. It can be an economical option to use DEHA for oxygen scavenging along with a neutralizing amine for controlling carbonic acid attack.
  2. Pretreatment Equipment: Since carbonic acid is a primary cause of corrosion in condensate systems, using pretreatment equipment to reduce or remove the sources of carbon dioxide up front can be very beneficial. A dealkalizer unit downstream of a water softener will reduce the alkalinity of the makeup water going to the boiler. A reverse osmosis unit will not only reduce the alkalinity but will also reduce other dissolved solids in the boiler makeup water allowing the system to run at higher cycles of concentration, which can save fuel and water. An economic analysis of which two equipment options is best would need to be conducted.
  3. Treatment Program Monitoring: Condensate monitoring will depend on the treatment methods you have used, but in any case, your system should be tested using the following methods:
  4. Testing soluble and insoluble iron levels Using condensate corrosion coupons Testing pH levels.

It is important to test the pH levels along various points in the condensate return system to avoid low pH areas that are more prone to corrosion. If a filming amine or oxygen scavenging DEHA is used, the residual should be measured.

Conclusion

These methods can provide system operators who want to protect both a capital investment and their day-to-day operations with a number of protective options, but the most effective protection comes from partnering with an industry expert such as Chem-Aqua.

Chem-Aqua is a global leader in custom-designed programs for boilercooling, and process water systems. Since 1919, our success has been built upon our Total System Approach, providing solutions for water treatment problems and improving water system efficiencies. Learn more about how we can help protect your systems at our website.

Read more at chemaqua.com

Energy: are you visible to AI?

Before they reach out, Energy buyers ask AI engines which vendors to trust. See how AI describes your company today, and where competitors show up instead.

Free workspace

You just read one expert. Imagine publishing your whole team.

This article was produced through MarketScale. Create a free workspace and turn your own team's expertise into articles, video, and social posts. No credit card, no demo required.

NPS +73 · 1,000+ creators · 38+ countries

What you get, free

Your own MarketScale Studio workspace
One video edit a month, on us
AI writing, editing, and publishing tools
In-platform coaching to learn the system

More Energy Insights

Clean energy investment hits $2.2 trillion in 2026, nearly doubling fossil fuel spending

Clean energy investment hits $2.2 trillion in 2026, nearly doubling fossil fuel spending

Global energy investment is projected to reach $3.4 trillion by 2026, with clean energy spending nearly doubling that of fossil fuels. The International Energy Agency's latest report highlights this trend, showing a significant shift towards sustainable energy sources.

  • 01Clean energy investment will reach $2.2 trillion in 2026.
  • 02Overall energy investment globally is expected to be $3.4 trillion by 2026.
  • 03Investment in clean energy will outpace fossil fuel spending almost two to one.

Jul 17, 2026

Solar hits 8.7% of global power, but fossil fuels still grew faster in 2025

Solar hits 8.7% of global power, but fossil fuels still grew faster in 2025

The Energy Institute's 2026 Statistical Review indicates that while renewable energy sources like solar accounted for 8.7% of global power in 2025, fossil fuel consumption continued to rise due to overall increases in energy demand. The report highlights the challenges in transitioning to renewables given the growing global energy needs.

  • 01Solar energy accounted for 8.7% of global power in 2025.
  • 02Fossil fuel consumption increased despite the growth in renewables.
  • 03Total energy demand grew at a rate faster than the integration of renewables.

Jul 17, 2026

Cornerstone Energy Services' 4th Annual Energy Transition Forum tackles reliability, decarbonization, and New England's grid future

Cornerstone Energy Services' 4th Annual Energy Transition Forum tackles reliability, decarbonization, and New England's grid future

Utility leaders, engineers, and regulators gathered at the 4th Annual Energy Transition Forum hosted by Cornerstone Energy Services to discuss important topics like gas planning and winter reliability. The forum focused on challenges and developments in achieving decarbonization and ensuring grid reliability in New England. Discussions highlighted the strategic directions for the region's energy future amidst the shift towards sustainable energy solutions.

  • 01The forum discussed New England's approach to gas planning and winter reliability in light of energy transition challenges.
  • 02Decarbonization and grid reliability were key focuses, emphasizing their importance in future energy planning.
  • 03Stakeholders included utility leaders, engineers, and regulators, addressing strategic energy choices for the region's future.

Jul 16, 2026

Explore More Energy Insights

Read more expert perspectives from across Energy.

Browse Energy Hub

For B2B teams

Your experts could be publishing here

Stories like this one run on content MarketScale captures from real practitioners. See how your team's expertise becomes coverage in Energy and beyond.

Book a 15-minute demo

Or call us. No forms required. We pick up. 214-945-2512