Primary Causes and How to Prevent Them In boiler systems, steam that has completed its work condenses back into liquid water called condensate.  This is a high-purity, high-heat-content water that makes sense to recycle into the boiler system whenever possible to save money, water, energy, and chemicals. Protecting your plant’s condensate return system is vital…

This story was produced through MarketScale. See how Energy teams put it to work with Customer Stories & Case Studies.

·
Share
5 Steps to Protect Your Condensate System from Destructive Corrosion

Free workspace

Turn your Energy expertise into content.

Record interviews, organize footage, and write with AI on a free trial of the MarketScale platform for qualifying companies. No demo required, no credit card.

Try it Free

Primary Causes and How to Prevent Them

In boiler systems, steam that has completed its work condenses back into liquid water called condensate. This is a high-purity, high-heat-content water that makes sense to recycle into the boiler system whenever possible to save money, water, energy, and chemicals.

Protecting your plant’s condensate return system is vital not only because it is a massive capital investment, but also because it can impact your day-to-day operations. The primary causes of destructive corrosion are carbonic acid attack and oxygen pitting. This corrosion can cause unexpected system shutdowns, affecting production timelines. Corroded systems are also less efficient, risking leaks and potentially catastrophic damage to the boiler as corrosion byproducts are carried into the feedwater.

Carbonic Acid Attack

Carbonic acid attack occurs when carbon dioxide from the steam condenses with the condensate to form carbonic acid. The carbon dioxide originates from the thermal breakdown of the carbonate alkalinity naturally present in the makeup water. Since the condensate is so pure, it requires very little dissolved carbon dioxide to lower the condensate pH into the corrosive range. The greater the makeup alkalinity, the greater the amount of carbon dioxide present in the steam, which increases the potential for carbonic acid attack in the condensate return system.

A carbonic acid attack is characterized by “grooving” of the condensate piping, which typically presents as thinning of the pipe at the threaded fitting. This same deterioration can also be spotted downstream of steam traps.

Oxygen Pitting

Another frequent type of corrosion is oxygen pitting, caused by dissolved oxygen in the condensate, which may occur when oxygen is not completely removed from the feedwater. Dissolved oxygen may also be present as a result of the vacuum created when steam condenses and cools, pulling oxygen-rich air into the system. Oxygen pitting is characterized by an intense, localized pitting that may or may not be covered by a tubercule. Due to the restrictive nature of oxygen pitting, it can cause rapid metal failure in a condensate system and is especially aggressive if the condensate pH is low.

Condensate System Protection

An effective protection and treatment plan can be divided into five main categories: neutralizing amines, filming amines, volatile oxygen scavengers, pretreatment equipment, and treatment program monitoring.

  1. Neutralizing Amines: The most common method of preventing a carbonic acid attack is through neutralizing amines. These chemicals, such as morpholine, cyclohexylamine, and diethylaminoethanol (DEAE), become volatile when mixing with steam and condense in the same way that the carbon dioxide does. They then neutralize the carbonic acid and increase the condensate pH. However, this process is ineffective in protecting against oxygen pitting.
  1. Filming Amines: A filming amine provides a protective barrier against both carbonic acid and oxygen. When using a filming amine, the pH is usually maintained between 6.0 and 7.5, so a neutralizing amine may still be required. Since the protective film formed by filming amines are susceptible to damage, it is critical to use corrosion coupons to monitor the effectiveness of corrosion control. Another significant limitation of filming amines is that they can be difficult to apply and cause fouling, particularly in systems where they have not been applied previously. A filming amine program should be initiated very gradually to help avoid this problem and users should be aware of the limitations.
  1. Volatile Oxygen Scavengers: A volatile oxygen scavenger such as DEHA (diethylhydroxyamine) can also be used to protect your condensate system against oxygen pitting. DEHA has fewer limitations than filming amines and can provide even better results since it both scavenges oxygen and passivates system metals, making them less susceptible to corrosion. It can be an economical option to use DEHA for oxygen scavenging along with a neutralizing amine for controlling carbonic acid attack.
  2. Pretreatment Equipment: Since carbonic acid is a primary cause of corrosion in condensate systems, using pretreatment equipment to reduce or remove the sources of carbon dioxide up front can be very beneficial. A dealkalizer unit downstream of a water softener will reduce the alkalinity of the makeup water going to the boiler. A reverse osmosis unit will not only reduce the alkalinity but will also reduce other dissolved solids in the boiler makeup water allowing the system to run at higher cycles of concentration, which can save fuel and water. An economic analysis of which two equipment options is best would need to be conducted.
  3. Treatment Program Monitoring: Condensate monitoring will depend on the treatment methods you have used, but in any case, your system should be tested using the following methods:
  4. Testing soluble and insoluble iron levels Using condensate corrosion coupons Testing pH levels.

It is important to test the pH levels along various points in the condensate return system to avoid low pH areas that are more prone to corrosion. If a filming amine or oxygen scavenging DEHA is used, the residual should be measured.

Conclusion

These methods can provide system operators who want to protect both a capital investment and their day-to-day operations with a number of protective options, but the most effective protection comes from partnering with an industry expert such as Chem-Aqua.

Chem-Aqua is a global leader in custom-designed programs for boiler, cooling, and process water systems. Since 1919, our success has been built upon our Total System Approach, providing solutions for water treatment problems and improving water system efficiencies. Learn more about how we can help protect your systems at our website.

Read more at chemaqua.com

Your experts belong here

Every story in MarketScale Energy starts with a company putting its field engineers, operations leads, and project developers on the record. Buyers are already reading this topic. The only question is whose experts they find.

Developers and operators shortlist on credibility, and your engineers give your sales team something real to send.

Book DemoSee how it works15 minutes, straight to a calendar.
B2B Weekly

The week in Energy, and sixteen other industries, every Monday.

Ten stories, one-line takes, five minutes. Free.

Energy: are you visible to AI?

Before they reach out, Energy buyers ask AI engines which vendors to trust. Explore how your experts, customers, and partners can become useful content for buyers and AI search.

Free Trial

You just read one Energy expert. Your company is full of them.

This article was produced through MarketScale. The same platform turns your field engineers, operations leads, and project developers into the articles, video, and social content Energy buyers are searching for. Start a free trial and see it with your own people. For qualifying companies, no credit card, no demo required.

NPS +73 · 1,000+ creators · 38+ countries

What your free trial includes

Hands-on access to the MarketScale platform
Media requests to your crowd, remote recording, AI writing tools
No demo required. No credit card.
For qualifying companies. Company confirmation required.

More Energy Insights

Solar panels installed in 2020 could supply 21% of solar silver by 2035

Solar panels installed in 2020 could supply 21% of solar silver by 2035

Recycling solar panels installed in 2020 could supply up to 21% of the silver needed for new panel production by 2035. Technical advances are making panel recycling more economic. Buyers and asset owners can start modeling recycled supply and retirement value.

  • 01Panels installed in 2020 could supply up to 21% of the silver needed for solar panel production in 2035, a 15-year lag that suggests recycled supply could be estimated from installation records.
  • 02European researchers estimate recycling could cover about 25% of cobalt and 15% of lithium, nickel and manganese supply by 2030.
  • 03A recycler's recovery rate means little without its purity: TNO's laser process reported roughly 97% yield with silver at 99.7% purity, the pairing that tells a manufacturer whether the metal is usable.

Oct 2, 2026

Massachusetts queue delays put 2027 solar tax credits at risk

Massachusetts queue delays put 2027 solar tax credits at risk

Catalyst Power says interconnection delays are now a tax-credit risk, not just a schedule risk. In Massachusetts, a project tied to a 2029 transmission upgrade could miss the Dec. 31, 2027 deadline that SEIA says now governs many solar projects, putting 30% to 50% of ITC value at risk.

  • 01SEIA says solar projects that begin construction after July 4, 2026 must be placed in service by Dec. 31, 2027.
  • 02FERC's cluster-study reforms set study deadlines and late-study penalties, but they do not guarantee a needed grid upgrade finishes before a project's tax clock runs out.

Oct 2, 2026

Only 33% of utility executives call asset management advanced, IFS survey finds

Only 33% of utility executives call asset management advanced, IFS survey finds

Fifty-seven percent of utility executives call AI critical to cutting costs. Only 33% rate their asset lifecycle management as advanced, and 49% report operational data silos.

  • 01Fifty-seven percent of utility executives call AI critical to cutting costs, but only 33% rate the asset management that AI would run on as advanced.
  • 02Half of executives say asset management runs in silos with limited predictive capability, suggesting early AI spend may go to data integration before models.
  • 03Pew says grid modernization capex is pressuring rates; it also says using DERs via virtual power plants could serve peak demand at 40%–60% of traditional costs and help defer or avoid some infrastructure upgrades.

Sep 30, 2026

Explore More Energy Insights

Read more expert perspectives from across Energy.

Browse Energy Hub

For B2B teams

Your experts could be publishing here

Stories like this one run on content MarketScale captures from real practitioners. See how your team's expertise becomes coverage in Energy and beyond.

Book a Demo

Or call us. No forms required. We pick up. 214-945-2512